Marco (tech)
Patel master bath: neo-angle measure
LaunchAI converts glass sketches and measure sheets into CAD drawings. Create panel drawings with dimensions, notches, holes and edgework for fabrication. The drawing is built from the supplied measurements, notes and specifications. Unclear details are flagged for your team to review.
For estimators, order desks and owners at residential and commercial glass shops
The techs left their sheets on your desk Friday. A neo-angle with top, middle and bottom widths and a level reading on each wall. A steam shower with a transom and "header?" in the margin. A vanity mirror at 60 x 36 with "cut out for plug" and no location. A GC email with a phone photo of a cracked storefront lite: "replace like for like, size is on the sticker." The sticker is in the photo. Half of it.
So you sit down with the hardware catalog and a calculator. Smallest width, minus the hinge gap, minus the strike gap, minus whatever the curb slope eats. Decide if the out-of-plumb wall gets an out-of-square panel or a wider gap. Notch for the hinges, holes for the handle, edgework, tempering. Then you type it all again into CRL Showers Online or Enclosures Online, or draw it in AutoCAD for the tempering plant, and fill their order form with the same numbers a third time.
Tempered glass can't be recut. Get one deduction wrong and the panel is scrap, the customer waits another two weeks on the remake, and the margin on that bathroom is gone. Which is why the only person who does this is the one person who never gets it wrong, and that person is buried.
What the job looks like today
Three widths, two plumb readings, a curb note and a hinge arrow.
Calculator, hardware catalog and a sticky note of your own gaps.
Panels, notches and holes in AutoCAD or the supplier's configurator.
Same numbers into the fabricator's form, by hand.
You find out at install, two weeks and one tempering run later.
Where it goes wrong
The tech measured it right. The trouble is what the sheet assumed you'd know.
"1/4 out" on the back wall. Leaning in at the top or out? Over the full height or just the last foot? That's the difference between an out-of-square panel and a 1/4" gap the customer will stare at every morning.
The tech stood inside the shower to draw it. The fabricator's form is drawn from outside. Swap the view and the door swings into the toilet.
Curbs are built to shed water in. A 1/8" slope across the door means the bottom edge, the sweep and the gap all change. The sheet says "curb 3 1/2" and nothing else.
A mirror outlet cutout needs a location from two edges and a size. Without them you're guessing, and a guessed hole in a 60 x 36 mirror is a new mirror.
Why it's still manual
Glass shops have good configurators and good CAD. Somebody still has to read the measure sheet into them.
Your CAD and quoting software
Waits for someone to type
AutoCAD, eShowers and Smart Glazier draw a panel with notches and holes quickly, once someone has decided the sizes. The deductions, the plumb readings and the curb are still worked out by hand.
Generic AI and OCR models
Confidently wrong
A generic AI model reads "36 1/4 T 36 B" as one number, drops the arrow on the plumb reading, and when the side wall has no reading it fills one in. On tempered glass, a plausible number is a remake.
Image-to-CAD converters
Traces lines, not intent
Image-to-CAD converters trace the sketched lines into a DXF. A tech's plan view isn't to scale and has no thickness, deductions or hinge side in it, so you redraw it anyway.
Measuring apps and configurators
Only if everyone uses them
CRL Showers Online and US Horizon Enclosures Online size standard layouts well. They still need someone to type the measure sheet in, and custom mirrors, transoms and storefront fall outside them.
How the agent does it
LaunchAI converts the sketch and its measurements into CAD geometry, applies your drawing standards and prepares the related order information. Missing dimensions and unclear notes are flagged for your team to review.
Widths, plumb readings, curb, hinge side and hardware, each with a confidence score.
Gaps, clearances and door limits from your rules tables, the same way every time.
In AutoCAD or your supplier's configurator, with notches and holes from your templates.
Glass, edgework, tempering and hardware into the fabricator's portal or form.
Confirm the one reading it flagged, and the order goes to tempering.
Caught at the desk
Today the order bounces when someone hits save. The agent runs the same checks first, fills what it can from a trusted source, and brings you only the one thing that needs a person.
Today
Order incomplete · cannot send to fabricator
Verify the following
With the agent
Opening closes
Back and side returns meet at 135°; the diagonal agrees within 1/16".
Wall out of plumb
Written "out of plumb 1/4?". Panel drawn 1/4" out of square at the top; confirm direction before ordering.
Deductions applied
Hinge gap, strike gap and curb clearance from your deduction table, shown line by line.
Door within hardware limits
24-1/8" door in 3/8" glass is inside your hinge maker's width and weight range.
Notches and holes located
2 hinge notches and handle holes placed from your hardware template.
Fabricator order filled
Sizes, flat polish edges, tempering and finish entered; PO from the job.
Human review
The paperwork on one side, the agent's drawing on the other, and every value it read in between, with the one it's unsure of called out.
Approval you asked for
The agent sized the door and two panels with your hardware deductions and drew the notches. One out-of-plumb reading needs confirmation.
Agent suggests: Approve after confirming the 1/4" out-of-plumb at the top of the back wall. Door and panel sizes follow your deduction table.
Dimensions read from sketch
Inputs and outputs
Your numbers
Change the numbers to match your shop.
Example values. Put in your own.
today with the agent: review only
Your software
LaunchAI converts sketches into drawings through your CAD and design workflow. Bring your software version, drawing standards and a sample sketch so we can confirm the conversion steps and outputs for your setup.
FAQ
Yes. LaunchAI agents use web portals and desktop software through the screen, with your logins, the way your order desk does. There's no integration to set up with the supplier.
You give it your gaps, clearances and door limits once, per hardware line. They live in a rules table you can change any time, and every glass size on the approval screen shows which rule it used.
It never guesses a glass size. It flags the gap, drafts a text to the tech, and holds that order until someone answers.
Whoever approves today: you, the estimator or the shop manager. Nothing goes to the fabricator or the tempering plant until a person signs off.
Same agent, different rules. Mirror cutouts, transom heights and storefront lites from a measure sheet or a photo of the old stamp, with anything it can't read put in front of a person.
No. The tech still measures the opening. The agent takes the sheet from there, so the person who knows glass reviews sizes instead of working them out.
Other industries
Send us last week's measure sheets.